A PHP Error was encountered

Severity: Warning

Message: Creating default object from empty value

Filename: models/publicacao_item.php

Line Number: 20

Influ?ncia do preparo do orif?cio piloto na ancoragem dos parafusos... » Isaúde
  Pesquisar Publicações Científicas  
  Especialidade: carregando especialidades...  Carregando...
Nome da revista:   Volume:   Número:
Acta Ortopédica Brasileira
2012-12-12 02:17:50

Influ?ncia do preparo do orif?cio piloto na ancoragem dos parafusos pediculares

Descrição: OBJETIVO: Avaliamos a influ?ncia do di?metro e do modo de prepara??o do orif?cio piloto na resist?ncia ao arrancamento e no torque de inser??o dos parafusos pediculares com di?metro interno c?nico. M?TODOS: Ensaios mec?nicos foram realizados com parafusos pediculares com alma c?nica e di?metro de 4,2mm e 5,2mm inseridos nos ped?culos vertebrais lombares de su?nos. O orif?cio piloto foi confeccionado com de broca e sondas (pontiaguda e cortante) com diferentes di?metros. RESULTADOS: Testando o parafuso de 4,2mm a perfura??o com orif?cio igual ou inferior ao menor di?metro interno do parafuso, aumentou o torque e a resist?ncia ao arrancamento. Perfura??es com diferentes instrumentos apresentaram comportamento semelhante. Perfura??es com sondas permitiram que orif?cios confeccionados com dimens?es superiores ao menor di?metro interno do parafuso apresentassem resist?ncia semelhante a das perfura??es com dimens?es iguais ao menor di?metro interno do implante, realizadas com sondas e brocas. CONCLUS?ES: Nos de 4,2 mm o di?metro e o modo de prepara??o do orif?cio influenciam o torque e a resist?ncia, nos de 5,2 mm apenas o torque de inser??o. N?o h? correla??o entre for?a de arrancamento e torque de inser??o. N?vel de evid?ncia II, Estudos terap?uticos - Investiga??o dos Resultados do Tratamento.OBJECTIVE: We evaluated the influence of the diameter and the preparation of the pilot hole on the resistance to the pulling out and the strength when inserting pedicle screws with conical internal diameter. METHODS: Mechanical experiments were performed with pedicle conical screws of 4.2 mm and 5.2 mm diameter. They were inserted in the vertebral pedicles of swine. The hole was manufactured with a drill and probes with different diameters. RESULTS: While testing the 4.2 mm screw, the perforation of holes with measure equal or inferior to the lesser internal diameter of the screw increased the torque and the resistance to pulling out. Perforations with different instruments have presented similar results. Perforations with probes allowed the holes manufactured with dimensions superior to the lesser internal diameter of the screw to show similar resistance to that of the perforations with dimensions equal to the lesser internal diameter of the implant, made with probes and drills. CONCLUSIONS: For 4.2 mm screws, the diameter and the preparation of the hole influence the torque and the resistance. For 5.2 mm screws, there is only influence on the insertion torque. There is no correlation between pulling out strength and insertion torque. Level of Evidence II, Therapeutic Studies - Investigating the Results of Treatment.

Volume: 0


Mais informações

  • Twitter iSaúde
publicidade
Jornal Informe Saúde

Indique o portal
Fechar [X]
  • Você está indicando a notícia: http://www.isaude.net
  • Para que seu amigo(a) receba esta indicação preencha os dados abaixo:

RSS notícias do portal  iSaúde.net
Receba o newsletter do portal  iSaúde.net
Indique o portal iSaúde.net
Notícias do  iSaúde.net em seu blog ou site.
Receba notícias com assunto de seu interesse.
© 2000-2011 www.isaude.net Todos os direitos reservados.