Caracteriza??o qu?mica e metalogr?fica dos a?os inoxid?veis de implantes removidos de pacientes

Descrição: OBJETIVO: Este trabalho estudou a composi??o qu?mica e metalogr?fica (microestrutura, tamanho de gr?o, teor de inclus?es) de a?os inoxid?veis austen?ticos, desenvolvidos para aplica??es como biomateriais, utilizados na fabrica??o de implantes ortop?dicos. M?TODO: Foram analisados doze implantes removidos de pacientes afetados por quadro inflamat?rio. As an?lises qu?micas foram desenvolvidas pelas t?cnicas Espectrometria de Emiss?o ?tica e Microan?lise por Dispers?o de Energia (EDS) e o tamanho de gr?o foi determinado por microscopia ?tica e Microscopia Eletr?nica de Varredura (MEV) conforme norma ASTM E 1382 97. RESULTADOS: Observou-se que, todos os implantes apresentavam tamanho de gr?o superior ao recomendado pela norma, constatou-se tamb?m a presen?a de ferrita delta em dez dos doze implantes removidos, que de acordo com a norma ASTM F138-92 n?o deveriam ser percebidas microscopicamente com um aumento de 100 vezes. CONCLUS?ES: Em oito casos existe forte indica??o de que as inflama??es foram desencadeadas pela corros?o por pite. Nivel de Evid?ncia III, Revis?o sistem?tica de Estudos .OBJECTIVE: This study examines the chemical and metallographic composition (microstructure, grain size, inclusion content) of austenitic stainless steel developed as biomaterials for used in the manufacture of orthopedic implants. METHOD: An analysis was carried out of twelve implants removed from patients affected by inflammation. Chemical analyses were carried out using Optical Emission Spectrometry and Energy Dispersive Microanalysis (EDS), and the grain size was determined by optical microscopy and scanning electron microscopy (SEM) according to ASTM Standard E 1382 97. RESULTS: It was observed that all the implants had a larger grain size than is recommended by the Standard. The presence of delta ferrite was also observed in ten of the twelve implants removed, which according to ASTM Standard F138-92, should not be perceived microscopically under magnification of 100x. CONCLUSIONS: In eight cases, there is a strong indication that the inflammation was triggered by pitting corrosion. Level of Evidence: Level III, Systematic review of studies.

Volume: 0


Mais informações

  • Twitter iSaúde
publicidade
Jornal Informe Saúde

Indique o portal
Fechar [X]
  • Você está indicando a notícia: http://www.isaude.net
  • Para que seu amigo(a) receba esta indicação preencha os dados abaixo:

RSS notícias do portal  iSaúde.net
Receba o newsletter do portal  iSaúde.net
Indique o portal iSaúde.net
Notícias do  iSaúde.net em seu blog ou site.
Receba notícias com assunto de seu interesse.
© 2000-2011 www.isaude.net Todos os direitos reservados.