A PHP Error was encountered

Severity: Warning

Message: Creating default object from empty value

Filename: models/publicacao_item.php

Line Number: 20

Meta-analysis: the diagnostic accuracy of critical flicker frequency... » Isaúde
  Pesquisar Publicações Científicas  
  Especialidade: carregando especialidades...  Carregando...
Nome da revista:   Volume:   Número:
Alimentary Pharmacology and Therapeutics
2013-01-07 15:56:29

Meta-analysis: the diagnostic accuracy of critical flicker frequency in minimal hepatic encephalopathy

Descrição: BackgroundMinimal hepatic encephalopathy (MHE) reduces quality of life, increases the risk of road traffic incidents and predicts progression to overt hepatic encephalopathy and death. Current psychometry-based diagnostic methods are effective, but time-consuming and a universal -gold standard- test has yet to be agreed upon. Critical Flicker Frequency (CFF) is a proposed language-independent diagnostic tool for MHE, but its accuracy has yet to be confirmed.AimTo assess the diagnostic accuracy of CFF for MHE by performing a systematic review and meta-analysis of all studies, which report on the diagnostic accuracy of this test.MethodsA systematic literature search was performed to locate all publications reporting on the diagnostic accuracy of CFF for MHE. Data were extracted from 2??2 tables or calculated from reported accuracy data. Collated data were meta-analysed for sensitivity, specificity, diagnostic odds ratio (DOR) and summary receiver operator curve (sROC) analysis. Prespecified subgroup analysis and meta-regression were also performed.ResultsNine studies with data for 622 patients were included. Summary sensitivity was 61% (95% CI: 55-67), specificity 79% (95% CI: 75-83) and DOR 10.9 (95% CI: 4.2-28.3). A symmetrical sROC gave an area under the receiver operator curve of 0.84 (SE?=?0.06). The heterogeneity of the DOR was 74%.ConclusionsCritical Flicker Frequency has a high specificity and moderate sensitivity for diagnosing minimal hepatic encephalopathy. Given the advantages of language independence and being both simple to perform and interpret, we suggest the use of critical flicker frequency as an adjunct (but not replacement) to psychometric testing.

Editorial: John Wiley & Sons, Inc.
Seção: Meta-analysis
Volume: 0
Página: 527 a 536


Mais informações

  • Twitter iSaúde
publicidade
Jornal Informe Saúde

Indique o portal
Fechar [X]
  • Você está indicando a notícia: http://www.isaude.net
  • Para que seu amigo(a) receba esta indicação preencha os dados abaixo:

RSS notícias do portal  iSaúde.net
Receba o newsletter do portal  iSaúde.net
Indique o portal iSaúde.net
Notícias do  iSaúde.net em seu blog ou site.
Receba notícias com assunto de seu interesse.
© 2000-2011 www.isaude.net Todos os direitos reservados.