A PHP Error was encountered

Severity: Warning

Message: Creating default object from empty value

Filename: models/publicacao_item.php

Line Number: 20

Association of Narrow Angles With Anterior Chamber Area and Volume... » Isaúde
  Pesquisar Publicações Científicas  
  Especialidade: carregando especialidades...  Carregando...
Nome da revista:   Volume:   Número:
Archives of ophthalmology
2011-05-09 19:51:34

Association of Narrow Angles With Anterior Chamber Area and Volume Measured With Anterior-Segment Optical Coherence Tomography [Clinical Sciences]

Assunto: Ophthalmology, Ophthalmological Disorders, Glaucoma, Ophthalmological Procedures, Ocular Imaging, Diagnosis

Descrição: Objectives  To describe the measurement of anterior chamber area and anterior chamber volume by anterior-segment optical coherence tomography and to investigate the association of these parameters with the presence of narrow angles.Methods  This was a cross-sectional study of subjects aged at least 50 years without ophthalmic symptoms recruited from a community clinic. All participants underwent standardized ocular examination and anterior-segment optical coherence tomography. Customized software was used to measure anterior chamber area (cross-sectional area bounded by the corneal endothelium, anterior surface of iris, and lens within the pupil) and anterior chamber volume (calculated by rotating the anterior chamber area 360° around a vertical axis through the midpoint of the anterior chamber area). An eye was considered to have narrow angles if the posterior pigmented trabecular meshwork was not visible for at least 180° on gonioscopy with the eye in the primary position.Results  A total of 1922 subjects were included in the final analyses, 317 (16.5%) of whom had narrow angles. Mean anterior chamber area (15.6 vs 21.1 mm2; P < .001) and anterior chamber volume (97.6 vs 142.1 mm3; P < .001) were smaller in eyes with narrow angles compared with those in eyes without narrow angles. After adjusting for age, sex, anterior chamber depth, axial length, and pupil size, smaller anterior chamber area (odds ratio, 53.2; 95% confidence interval, 27.1-104.5) and anterior chamber volume (odds ratio, 40.2; 95% confidence interval, 21.5-75.2) were significantly associated with the presence of narrow angles.Conclusion  Smaller anterior chamber area and anterior chamber volume were independently associated with narrow angles in Singaporeans, even after controlling for other known ocular risk factors.

Identificador: i
Editorial: American Medical Association
Seção: Clinical Sciences
Número: 5
Volume: 129
Página: 569 a 574
Autor: Wu, R.-Y., Nongpiur, M. E., He, M.-G., Sakata, L. M., Friedman, D. S., Chan, Y.-H., Lavanya, R., Wong, T.-Y., Aung, T.


Mais informações

  • Twitter iSaúde
publicidade
Jornal Informe Saúde

Indique o portal
Fechar [X]
  • Você está indicando a notícia: http://www.isaude.net
  • Para que seu amigo(a) receba esta indicação preencha os dados abaixo:

RSS notícias do portal  iSaúde.net
Receba o newsletter do portal  iSaúde.net
Indique o portal iSaúde.net
Notícias do  iSaúde.net em seu blog ou site.
Receba notícias com assunto de seu interesse.
© 2000-2011 www.isaude.net Todos os direitos reservados.